array(141) { ["ID"]=> string(5) "10788" ["TITLE"]=> string(32) "6-30v Zaman Ayarlı Röle Kartı" ["IS_NEW_PRODUCT"]=> string(1) "1" ["IS_ACTIVE"]=> string(1) "1" ["VARIANT_ID"]=> int(0) ["CATEGORY_ID"]=> string(3) "746" ["CATEGORY_ID_PATH"]=> string(8) "50 > 746" ["CATEGORY_IDS"]=> string(3) "746" ["PRICE_SELL"]=> float(28.6332) ["PRICE_BUY"]=> float(0) ["PRICE_NOT_DISCOUNTED"]=> float(28.6332) ["SUPPLIER_PRODUCT_CODE"]=> string(5) "10788" ["CURRENCY_ID"]=> string(1) "1" ["VAT"]=> int(18) ["HAS_IMAGE"]=> string(1) "1" ["HAS_VARIANT"]=> int(0) ["DISPLAY_VAT"]=> string(1) "0" ["BRAND"]=> string(5) "China" ["BRAND_ID"]=> string(3) "253" ["BRAND_URL"]=> string(5) "china" ["BRAND_IMAGE"]=> string(0) "" ["MODEL"]=> string(0) "" ["MODEL_ID"]=> string(1) "0" ["STOCK"]=> string(2) "22" ["STOCK_UNIT"]=> string(4) "Adet" ["STOCK_UNIT_ID"]=> string(1) "1" ["CBM"]=> string(1) "1" ["STOCK_INCREMENT"]=> float(1) ["PRODUCT_CODE"]=> string(6) "T10788" ["SHORT_DESCRIPTION"]=> string(0) "" ["ADDITIONAL_FIELD_1"]=> string(0) "" ["ADDITIONAL_FIELD_2"]=> string(0) "" ["ADDITIONAL_FIELD_3"]=> string(0) "" ["BARCODE"]=> string(0) "" ["STORE_ID"]=> string(1) "0" ["IS_DISCOUNT_ACTIVE"]=> int(0) ["IS_DISPLAY_DISCOUNTED_ACTIVE"]=> string(1) "0" ["DISCOUNT_PERCENT"]=> int(0) ["DISCOUNT_PERCENT_RAW"]=> int(0) ["CARGO_FREE"]=> string(1) "0" ["CARGO_FREE_MEMBER"]=> string(1) "0" ["CARGO_FREE_VENDOR"]=> string(1) "0" ["DELIVERY_TIME"]=> string(0) "" ["REGISTRATION_DATE"]=> int(1519477160) ["IS_MULTIPLE_DISCOUNT_ACTIVE"]=> int(0) ["MIN_SALE_COUNT"]=> string(1) "0" ["MAX_SALE_COUNT"]=> string(1) "0" ["MIN_ORDER_COUNT"]=> int(1) ["MAX_ORDER_COUNT"]=> int(99999) ["CATEGORY_URL"]=> string(13) "role-kartlari" ["CATEGORY_NAME"]=> string(15) "Röle Kartları" ["CATEGORY_PATH"]=> string(8) "Röle > " ["FILTER_CATEGORY_ID"]=> string(1) "0" ["URL"]=> string(29) "6-30v-zaman-ayarli-role-karti" ["MODEL_URL"]=> string(8) "?model=0" ["IN_STOCK"]=> bool(true) ["IS_DISPLAY_PRODUCT"]=> string(1) "0" ["VARIANT_NAME"]=> string(0) "" ["SHOW_VENDOR"]=> string(1) "0" ["SHOW_PROMOTION"]=> string(1) "0" ["ACTIVE_ON_GROUPS"]=> string(3) "-0-" ["COMMENT_RANK"]=> string(1) "0" ["S1"]=> string(1) "0" ["SYMBOL_DATA1"]=> string(127) "" ["SYMBOL_TAG1"]=> string(15) "Ücretsiz Kargo" ["S2"]=> string(1) "0" ["SYMBOL_DATA2"]=> string(129) "" ["SYMBOL_TAG2"]=> string(14) "Stoktan Teslim" ["S3"]=> string(1) "0" ["SYMBOL_DATA3"]=> string(130) "" ["SYMBOL_TAG3"]=> string(18) "Kampanyalı Ürün" ["S4"]=> string(1) "0" ["SYMBOL_DATA4"]=> string(128) "" ["SYMBOL_TAG4"]=> string(16) "Aynı Gün Kargo" ["S5"]=> string(1) "0" ["SYMBOL_DATA5"]=> string(0) "" ["SYMBOL_TAG5"]=> string(0) "" ["S6"]=> string(1) "0" ["SYMBOL_DATA6"]=> string(0) "" ["SYMBOL_TAG6"]=> string(0) "" ["S7"]=> string(1) "0" ["SYMBOL_DATA7"]=> string(0) "" ["SYMBOL_TAG7"]=> string(0) "" ["S8"]=> string(1) "0" ["SYMBOL_DATA8"]=> string(0) "" ["SYMBOL_TAG8"]=> string(0) "" ["S9"]=> string(1) "0" ["SYMBOL_DATA9"]=> string(0) "" ["SYMBOL_TAG9"]=> string(0) "" ["S10"]=> string(1) "0" ["SYMBOL_DATA10"]=> string(0) "" ["SYMBOL_TAG10"]=> string(0) "" ["PRICE_GUEST"]=> float(28.6332) ["IMAGE_LIST"]=> array(1) { [0]=> array(7) { ["ID"]=> string(5) "30155" ["SMALL"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-K.jpg" ["MEDIUM"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-O.jpg" ["BIG"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-B.jpg" ["TITLE"]=> string(32) "6-30v Zaman Ayarlı Röle Kartı" ["VARIANT_IDS"]=> array(0) { } ["VARIANT_TYPE_ID"]=> string(1) "0" } } ["IMAGE"]=> array(7) { ["ID"]=> string(5) "30155" ["SMALL"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-K.jpg" ["MEDIUM"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-O.jpg" ["BIG"]=> string(67) "https://www.direnc.net/6-30v-zaman-ayarli-role-karti-30155-10-B.jpg" ["TITLE"]=> string(32) "6-30v Zaman Ayarlı Röle Kartı" ["VARIANT_IDS"]=> array(0) { } ["VARIANT_TYPE_ID"]=> string(1) "0" } ["IMAGE_COUNT"]=> int(1) ["IMAGE_RATIO"]=> float(1) ["PRICE_CREDIT_CART"]=> float(28.6332) ["PRICE_MONEY_ORDER"]=> float(28.6332) ["MONEY_ORDER_PERCENT"]=> int(0) ["IS_MONEY_ORDER_ACTIVE"]=> bool(false) ["CURRENCY"]=> string(3) "USD" ["TARGET_CURRENCY"]=> string(2) "TL" ["PRICE_SELL_DEFAULT"]=> float(28.6332) ["PRICE_RAW"]=> float(6.42) ["TARGET_CURRENCY_ORIGINAL"]=> string(2) "TL" ["VARIANT_FEATURE1_LIST"]=> array(0) { } ["VARIANT_FEATURE2_LIST"]=> array(0) { } ["VARIANT_FEATURE1_SELECTED"]=> string(0) "" ["VARIANT_FEATURE2_SELECTED"]=> string(0) "" ["VARIANT_DATA"]=> string(147) "{"vat":18,"m_o_p":0,"variant_ids":[],"variant_prices":[],"buying_prices":[],"not_discounted_prices":[],"variant_supplier_codes":[],"active_ids":[]}" ["HAS_MAGNIFIER"]=> string(1) "0" ["SUPPLIER_ID"]=> string(1) "0" ["GENDER"]=> string(1) "0" ["DEAL"]=> string(1) "0" ["DEAL_START_DATE"]=> string(19) "01.01.1970 02:00:00" ["DEAL_END_DATE"]=> string(19) "01.01.1970 02:00:00" ["MULTIPLE_DISCOUNT"]=> array(0) { } ["COMBINATION_ID"]=> int(0) ["PERSONALIZATION_ID"]=> int(0) ["IS_PERSONALIZATION_ACTIVE"]=> bool(false) ["VARIANT_FEATURE1_TITLE"]=> string(0) "" ["VARIANT_FEATURE2_TITLE"]=> string(0) "" ["CAN_ADD_CART_IN_LIST"]=> bool(false) ["DETAIL"]=> string(27686) "Product Description
  • Material: Electrical components
  • Product introduction:
  • 1. Operating voltage: 6--30V
  • 2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit
    system (short circuit can also connect with a ground common)
  • 3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A
  • 4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever
  • Warning: Relay contact is passive and electricity production; 1 channel has the control function on / off
     
  • Operation mode:
  • P1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation:
  • 1) P1.1: signal being triggered again is not effective
  • 2) P1.2: signal being triggered again, start time again
  • 3) P1.3: signal being triggered again, reset; disconnect relay, stop timing
  • P2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay
  • P3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set
  • P3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set
  • Q4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared
     
  • Time interval:
  • 0.1 s (minimum) ~ 999 min (maximum) continuously adjustable
  • how to choose the time interval:
  • in the selection of parameter set interface mode, and press the STOP button to select the time
  • xxx. if the decimal point is in some place, the time interval is s-1 999 s
  • xx. x is decimal place is ten, the time interval is 0.1 s 99.9 s-
  • x. x. x is the decimal point are all on, the time interval is 1 min-999 min
  • parameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, "---" is unlimited cycle)
  • How to set the parameter:
  • 1. First make sure relay operation mode
  • 2. According to the operaiting relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come intot main interface); long press SET key two seconds and then looen enter selection interface mode; by pressing UP, DOWN key to choose the mode setting 
    (P1.1 ~ P4)
  • 3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash 
    (OP power in time; CL power off time; LOP cycle times, "---" is unlimited cycle ); by UP, DOWN to set the parameter value, support long press 
    (increase or decrease quickly) and press slightly (increase or decrease of 1 unit); after setting the parameter value by short press the STOP key to choose decimal place; choose the time interval (corresponding time interval is 0.1 s-999 min); Short press SET to set the current mode next parameter, the process is the same as above
  • 4. After the setting mode parameter, press and hold the SET button then hold the current configuration mode will flash, then go back to the main interface; define success parameter
    main interface: when the relay does not work, it will show "000" (no decimal point); the operating state relay, the screen has a decimal point
  • Mode Select Interface: press and hold the SET key to enter; after setting, long press the SET button back on main interface
     
  • Expansion Function Key STOP:
  • Activate Relay mode:
  • 1. NO: PO in power over time, relay can be connected
  • 2. OFF: relay is not allowed to connect, when in the off state
    in short main interface press the STOP key to achieve turn ON and OFF, current state will flash; then back to the main interface 
    (this function is a function of sudden stop, 1 key to turn off the relay)
  • Sleep Mode:
  • C-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well
  • The d-Normal Mode: nixie tube show ever
  • Note: Press and hold STOP button for 2 seconds can achieve change from C-P to O-d; Current state will flash and then return to the main interface
  • Size: 6.3*3.8*1.5cm/2.48"*1.50"*0.59"
  • No retail package
" ["DOCUMENT_INFO"]=> string(0) "" ["WARRANTY_INFO"]=> string(0) "" ["DELIVERY_INFO"]=> string(0) "" ["DELIVERY_DAY"]=> string(0) "" ["IS_VIDEO_ACTIVE"]=> string(1) "0" ["NOTES"]=> string(0) "" ["TOTAL_SALES"]=> string(1) "8" ["SEO_TITLE"]=> string(72) "6-30v Zaman Ayarlı Röle Kartı Uygun Fiyatıyla Satın Al - Direnc.net" ["SEO_KEYWORDS"]=> string(0) "" ["SEO_DESCRIPTION"]=> string(236) "6-30v Zaman Ayarlı Röle Kartı ürününü uygun fiyatı, hızlı kargo seçeneği ile Röle Kartları kategorisinden online olarak Türkiye'nin en büyük elektronik komponent satış sitesi Direnc.net'ten hemen satın alabilirsiniz." ["TAGS"]=> array(0) { } ["IS_ORDER_NOTE_ACTIVE"]=> bool(false) ["IS_CASH_POINT_ACTIVE"]=> bool(false) ["IS_RELATED_PRODUCTS_ACTIVE"]=> bool(false) ["IS_POPUP_PHOTO_ACTIVE"]=> string(1) "1" ["DISPLAY_GAIN"]=> bool(false) }

6-30v Zaman Ayarlı Röle Kartı

Marka/Menşei: China
Stok Kodu : 10788
28,63 TL +KDV
33,79 TL KDV Dahil
  • Ürün Özellikleri
  • Ödeme Seçenekleri
  • Yorumlar (0)
  • Resimler
  • Product Description
    • Material: Electrical components
    • Product introduction:
    • 1. Operating voltage: 6--30V
    • 2. Trigger Signal Source: High Level Trigger (3.0 V-24 V), signal ground and system ground are not common, which can increase anti-interference abilit
      system (short circuit can also connect with a ground common)
    • 3. Output Capacity: can control no more than DC 30V 5A AC or 220 V devices 5A
    • 4. Optocoupler Isolation: improve the anti-interference ability, after the parameter setting, it will memory forever
    • Warning: Relay contact is passive and electricity production; 1 channel has the control function on / off
       
    • Operation mode:
    • P1: After triggered signal, power relay on time OP, then turn off; within the OP period following operation:
    • 1) P1.1: signal being triggered again is not effective
    • 2) P1.2: signal being triggered again, start time again
    • 3) P1.3: signal being triggered again, reset; disconnect relay, stop timing
    • P2: giving the trigger signal, the time after shutdown relay CL power relay OP time; then timing, turn off the relay
    • P3.1: give the trigger signal after the power relay on time OP, CL shutdown time relay; then operating cycle above cycle gaive signal again, shutdown relay stop timing; cycle times (LOP) can be set
    • P3.2: after connecting. no need to trigger signal, power relay on time OP, CL shutdown time relay; then the operating cycle above timea cycle (LOP) can be set
    • Q4: keeping the function of the signal; if there is no trigger signal, the time will be canceled, relay stay connected; when the signal disappears, timing OP turn off the relay; over time, if no signal again, the time is cleared
       
    • Time interval:
    • 0.1 s (minimum) ~ 999 min (maximum) continuously adjustable
    • how to choose the time interval:
    • in the selection of parameter set interface mode, and press the STOP button to select the time
    • xxx. if the decimal point is in some place, the time interval is s-1 999 s
    • xx. x is decimal place is ten, the time interval is 0.1 s 99.9 s-
    • x. x. x is the decimal point are all on, the time interval is 1 min-999 min
    • parameter Introduction: OP power over time, turn off time CL, LOP cycle times (1-999 times, "---" is unlimited cycle)
    • How to set the parameter:
    • 1. First make sure relay operation mode
    • 2. According to the operaiting relay mode, the main interface (power module will flash current operating mode; standard mode P1.1, then come intot main interface); long press SET key two seconds and then looen enter selection interface mode; by pressing UP, DOWN key to choose the mode setting 
      (P1.1 ~ P4)
    • 3. After selecting the mode, press short SET to set the corresponding parameter, then the parameter you want to set will flash 
      (OP power in time; CL power off time; LOP cycle times, "---" is unlimited cycle ); by UP, DOWN to set the parameter value, support long press 
      (increase or decrease quickly) and press slightly (increase or decrease of 1 unit); after setting the parameter value by short press the STOP key to choose decimal place; choose the time interval (corresponding time interval is 0.1 s-999 min); Short press SET to set the current mode next parameter, the process is the same as above
    • 4. After the setting mode parameter, press and hold the SET button then hold the current configuration mode will flash, then go back to the main interface; define success parameter
      main interface: when the relay does not work, it will show "000" (no decimal point); the operating state relay, the screen has a decimal point
    • Mode Select Interface: press and hold the SET key to enter; after setting, long press the SET button back on main interface
       
    • Expansion Function Key STOP:
    • Activate Relay mode:
    • 1. NO: PO in power over time, relay can be connected
    • 2. OFF: relay is not allowed to connect, when in the off state
      in short main interface press the STOP key to achieve turn ON and OFF, current state will flash; then back to the main interface 
      (this function is a function of sudden stop, 1 key to turn off the relay)
    • Sleep Mode:
    • C-P Sleep mode: within 5 minutes, no operation; nixie tube will close auto display, and a function program well
    • The d-Normal Mode: nixie tube show ever
    • Note: Press and hold STOP button for 2 seconds can achieve change from C-P to O-d; Current state will flash and then return to the main interface
    • Size: 6.3*3.8*1.5cm/2.48"*1.50"*0.59"
    • No retail package
Benzer Ürünler
T-Soft E-Ticaret Sistemleriyle Hazırlanmıştır.